200,000 BTU Waste Oil Boiler

Can be used for In-floor radiant heat, Car and truck washes, Paint booths, Ice prevention and melt, Heating, Make-up air, Evaporation, Potable hot water, Supplement to HVAC systems

200B

BTU Input

200,000 BTU/58.3 kW per hour

Fuel Flow Rate

1.4 gallons/hour (5.3 liters/hour)

Water Output Temp. (max)

230 F /110 C

Operating Pressure

Low pressure, 30 psi

Click here for this model's SPECIFICATIONS

BOILER

ENGLISH UNIT

METRIC UNIT

BTU Input

200,000 BTU/hour

58.3KW/hour

Fuel Flow Rate

1.4 gallons/hour

5.3 litres/hour

Water Output Temp. (max)

230 F

110 C

Domestic Hot Water Output

4.0 gallons per minute at 100 F temp rise

15 liters per minute at 37.8 C temp rise

Boiler Capacity

30 gallons

114 Litres

Inlet Water Temp.

140 F minimum

60 C minimum

Exhaust Flue Diameter

8" diameter

20.32cm diameter

System Dimensions

45"Hx32"Wx50"D

114 x 82 x 127cm

Shipping Weight

790lbs

358.34kg

Operating Pressure

Low Pressure 30 psi

Commonly Used Fuels

Used crankcase oils, ATF, No. 2 fuel oil, up to 90 weight gear oil and diesel fuel 

Electrical Req.

115 VAC 60Hz, 25 amps maximum dedicated circuit

Regulation and Certification

EPA-approved
UL-listed system
ASME-certified vessel
Canadian Registration (CRN)

Warranty

10 years on heat exchanger, five years full and five years prorated
Three years on parts

Click here for this model's IMAGE GALLERY

Click on the images below for a larger version.



375,000 BTU Waste Oil Furnace

Can be used for In-floor radiant heat, Car and truck washes, Paint booths, Ice prevention and melt, Heating, Make-up air, Evaporation, Potable hot water, Supplement to HVAC systems

375B

BTU Input

375,000 BTU / 109 kW per hour

Fuel Flow Rate

2.7 gallons/hour (10.2 liters/hour)

Water Output Temp. (max)

230 F /110 C

Operating Pressure

Low pressure, 30 psi

Click here for this model's SPECIFICATIONS

BOILER

ENGLISH UNIT

METRIC UNIT

BTU Input

375,000 BTU/hour

110KW/hour

Fuel Flow Rate

2.7 gallons/hour

10.2 litres/hour

Water Output Temp. (max)

230 F

110 C

Domestic Hot Water Output

6.0 gallons per minute at 100 F temp rise

22 liters per minute at 37.8 C temp rise

Boiler Capacity

43 gallons

162.75 Litres

Inlet Water Temp.

140 F minimum

60 C minimum

Exhaust Flue Diameter

8" diameter

20.32cm diameter

System Dimensions

42"Hx28"Wx60"D

107 x 71 x 152cm

Shipping Weight

1042lbs

472.64kg

Operating Pressure

Low Pressure 30 psi

Commonly Used Fuels

Used crankcase oils, ATF, No. 2 fuel oil, up to 90 weight gear oil and diesel fuel 

Electrical Req.

115 VAC 60Hz, 25 amps maximum dedicated circuit

Regulation and Certification

EPA-approved
UL-listed system
ASME-certified vessel
Canadian Registration (CRN)

Warranty

10 years on heat exchanger, five years full and five years prorated
Three years on parts

Click here for this model's IMAGE GALLERY

Click on the images below for a larger version.



499,000 BTU Waste Oil Furnace

Can be used for In-floor radiant heat, Car and truck washes, Paint booths, Ice prevention and melt, Heating, Make-up air, Evaporation, Potable hot water, Supplement to HVAC systems

500B

BTU Input

499,000 BTU/146 kW per hour

Fuel Flow Rate

3.6 gallons/hour (13.6 liters/hour)

Water Output Temp. (max)

230 F /110 C

Operating Pressure

Low pressure, 30 psi

Click here for this model's SPECIFICATIONS

BOILER

ENGLISH UNIT

METRIC UNIT

BTU Input

499,000 BTU/hour

146KW/hour

Fuel Flow Rate

3.6 gallons/hour

13.6 litres/hour

Water Output Temp. (max)

230 F

110 C

Domestic Hot Water Output

One coil: 8.0 gallons per minute at 100 F temp rise
Two coils: 16.0 gallons/min at a lower temp.

One coil: 22 liters per minute at 37.8 C temp rise
Two coils: 60 litres/minute at a lower temp.

Boiler Capacity

52 gallons

200 Litres

Inlet Water Temp.

140 F minimum

60 C minimum

Exhaust Flue Diameter

10" diameter

25.4cm diameter

System Dimensions

45"Hx32"Wx68"D

114 x 82 x 173cm

Shipping Weight

1160lbs

526.17kg

Operating Pressure

Low Pressure 30 psi

Commonly Used Fuels

Used crankcase oils, ATF, No. 2 fuel oil, up to 90 weight gear oil and diesel fuel 

Electrical Req.

115 VAC 60Hz, 25 amps maximum dedicated circuit

Regulation and Certification

EPA-approved
UL-listed system
ASME-certified vessel
Canadian Registration (CRN)

Warranty

10 years on heat exchanger, five years full and five years prorated
Three years on parts

Click here for this model's IMAGE GALLERY

Click on the images below for a larger version.


Learn more about Waste Oil Boilers on EnergyLogic Corporate Site

Standard Features

Only our Systems Include These Features - Standard

  • ¼" Carbon Steel Shell
  • Easily Integrated Domestic Hot Water Coil
  • Flame Retention Head
  • Hour Meter
  • Integrated Air Compressor
  • Non-Condensing
  • Patented Accutemp Preheater
  • Removable Rear Cleanout Panel
  • Small Footprint, fit into more existing structures than any other brand
  • Specialized Spin-On waste oil filter
  • Stackable
  • Steadyflo Metering Fuel Pump
  • Swing Open Boiler Door
  • Wet Floor Based Heat Exchanger

Advantages

Easiest Maintenance

Unlike other brands, our boilers have no hidden passageways or difficult tubes that are impossible to work around and which rot quickly. In fact, other brands are so difficult to clean, you'll end up taking shortcuts that immediately reduce efficiency and can lead to irreparable damage.

The Industry's Best Warranty

EnergyLogic gives you three years on parts and ten years on the combustion chamber, which means you’re covered for three entire heating seasons, versus just one. That’s triple what any other brand offers.

Built-in Versatility

Our boilers can provide the heat for radiant floor systems, fan coil units, snow melt for sidewalks and parking lots, hot water for car washes and high volume hot water pressure washing. We have even heated a few ponds for aquaculture. EnergyLogic boilers are capable of running as a closed and open loop system at the same time. They can be linked in numerous combinations with other models and even other fuel type boilers.

Boilers Spec Sheet
Learn More from EnergyLogic

© 2017 - EnergyLogic Canada Toll Free: 800-311-8828 or Email